český Deutsch English Español Francais Italiano Português slovenský
Gas leak detector, gas leak detector spray, gas leak detector ibiotec, oxygen leak detector, oxygen leak detector fluid, oxygen leak detector spray
Last update: 2023/06/13 09:38

GAS LEAK DETECTION SPRAY

ANTI-CORROSION, ANTI-OXIDATION, SUITABLE FOR ALL MATERIALS

GELATINISED TO ALLOW DETECTION IN ELEVATED SPACES AND VERTICAL SURFACES

CAN BE USED ON PIPES AND PURE OXYGEN CONNECTIONS UP TO 150 bar

HIGHLY SENSITIVE, PRECISELY LOCATE LEAKS

FAR EXCEEDS PERFORMANCE OF AN ELECTRONIC SENSOR

 

 

DESCRIPTION

DETECT 1000 leak detector is designed to enable professionals to carry out all types of test.

It is formulated to ensure ideal operation with high sensitivity, and also for macro-leaks requiring high surface tension.

Usable on all gases except pure oxygen at high pressure (> 150 bar).

All fluids (liquids and gases), even if they are not pressurised, naturally seek to escape from a container, especially if it has even the slightest of discontinuities. The result is a leak.

The integrity of a container is thus its ability to resist the flow of the fluid enclosed within it. In practice this function is more easily defined by its converse, namely the permeability of the container, i.e. the extent to which it allows its contents to escape or leak. It is easy and convenient to distinguish between two types of integrity for a container, depending on the surface continuity with the fluid:

Volumetric integrity, relating to the continuous surfaces of the container.

Integrity of an assembly or link, i.e. at the join between two continuous surfaces, broken down into static integrity and dynamic integrity during translation or rotation.

Note that it is impossible to obtain theoretically perfect integrity (especially with gases), due to the molecular nature of fluids.

"Absolute integrity" is an unrealistic statement that should be avoided. This does not exclude very high integrity levels, though; these may be defined in three classes: strict, relative, controlled.

It is, however, important to realise that a leak generally contains a random component, and that it often evolves over time. The leak will not be the same at the start of the mechanism’s life cycle as at the end. Accordingly, it is always useful to specify the maximum acceptable limits and to carry out continuous checks.

This detection aerosol can be used to measure all gas leaks, and is categorised as a general method not requiring special equipment.

It makes use of the spray and bubble method. The cost of a test is low compared to the investment. The method is highly reliable and offers excellent sensitivity; it can be used on any site.

Note that in extreme cases, if the pressure inside the bubble is close to atmospheric pressure, the bubble may only start to form once the pressure from the leak is sufficient to overcome the surface tension.

 

PROPERTIES

Highly dependable leak testing fluid.

Suitable for use on pure oxygen up to 150 bar.

Non-flammable.


FIELDS OF USE

Suitable for leak testing of volumes, assemblies and static or dynamic connections. Sleeves, screwed assemblies, welds, gaskets, hoses, crimped couplings, quick couplings, pressure gauges, valves, hoses, compressor tanks, radiators, manifolds, low temperature coils, air conditioners, heat exchangers, hollow bodies, assemblies with gaskets.

Gas cylinders, diving equipment, braking systems, tyres, pressure relief valves.

Also used to detect porous ducts, hoses and pipework.

 

                             Download the data sheet

 

TYPICAL PHYSICAL AND CHEMICAL PROPERTIES

PROPERTIE

STANDARD

VALUE

MEASUREMENT (UNIT)

Appearance

Visual

Liquid, clear

-

Colour

Visual

Amber

-

Odour

-

None

-

Density at 25°C

  NF EN ISO 12185

1002

g/l

Concentration of active ingredients

-

97

%

pH (neat)

NF T90-008

8.3

-

Flow Time Viscosity Cup 3

NF EN ISO 2431

23

s

Refractive index

ISO 5661

1.351

Indicator

Freezing point

ASTM D 97

-11

°C

Hydrocarbon content

LPCH

0

%

Phosphate Content

LPCH

0

%

Chlorine content

GCMS

 0 

ppm

Heavy metals and metalloid content

GCMS

0

ppm

COD Chemical Oxygen Demand

NFT 90101

6830

mgO2/l

BOD 5 Biological Oxygen Demand after 5 days

NF EN 1899-1

1120

mgO2/l

TSS Total Suspended Solids

NF EN 872

<2

mg/l

VSS Volatile Suspended Solids

 

<0.2

mg/l

Total Kjeldahl Nitrogen (TKN)

NF EN 25663

405

mgN/l

ThOD Theoretical Oxygen Demand (Seawater)

ISO 15705

7300

mgO2/l

Additional characteristics

Surface tension at 20°C

ISO 6295

21.9

Dynes/

Refractive index

ISO 5661 

1.3420

-



PRESENTATION

 

 

 

 

 

Aerosol 650 ml

 

Gas leak detector, gas leak detector spray, gas leak detector ibiotec, oxygen leak detector, oxygen leak detector fluid, oxygen leak detector spray

  

Looking for another product ?

Discover our entire range by clicking on the photo

Gas leak detector, gas leak detector spray, gas leak detector ibiotec, oxygen leak detector, oxygen leak detector fluid, oxygen leak detector spray

 

Manufacturing, lubrification, cleansing, protection,
IBiotec
® Tec Industries® Service
offers a wide range of products reserved for industrial area

 


 If you wish for :

 

a free sample
a technical advice
a product data sheet
a safety data sheet

 

- Please contact us -

 


IBiotec® Tec Industries®Service
manufacturer of technical chemical products.
Welcome to our website.



IBiotec® Tec Industries®Service is on : YOUTUBE